MB QUART QAA1000 User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
INST
ALLATION
INPUT LEVEL SENSITIVITY
The input level sensitivity for the MB Quart Q Series amplifiers is 200mV to 20V. This allows a wide range of
input signal compatibility from traditional source units to tomorrow's switching supply-based devices. When
the input sensitivity switch is set to “LOW” the range of the inputs is 200mV to 2.0 Volts, when in “HIGH”, the
RCA will accept 2.0 Volts to 20 volts! Please be sure to closely follow the instructions in the gain setting
section that advises to initially use the “HIGH” input range before trying “LOW” as this may damage the
sensitive electronics on the input of the amplifier. If your source unit has only speaker level outputs for
connection, be aware that typical source units have a balanced output (sometimes known as ‘BTL’) with a
reference voltage of 6.0V DC. The input to the MB Quart amplifier references ground so connecting the
speaker level leads to the RCA may cause damage to the source unit and/or amplifier.
CAUTION: Do not attempt to connect the source units speaker leads directly to the RCA connections
of this amplifier, as damage to the source unit and/or the amplifier may result.
° Speaker outputs are wired in
parallel internally.